[Top] [Prev] [Next] [Contents] [Index]
TOKENRING Messages
TOKENRING messages pertain to Token-Ring communications. If you are looking for a message that refers to the TOKENRING module but does not appear here, refer to "Messages Common to All Modules".
ACCESS, adapter access violation
- Severity:
- Error
- Explanation:
- The X server attempted to access Token-Ring reserved, read-
only memory.
- User Action:
- If you encounter this message, please contact NCD Technical
Support.
ADAPTERFAIL, PCMCIA adapter initialization failed
- Severity:
- Fatal
- Explanation:
- The Token-Ring adapter failed or the X server has detected an
internal error.
- User Action:
- If you encounter this message, please contact NCD Technical
Support.
ADDRESS, address for this unit: 00:00:E5:nn:nn:nn
- Severity:
- Information
- Explanation:
- The terminal is using the specified Token-Ring address.
- User Action:
- None
CHECK, adapter CHECK error: hex_values
- Severity:
- Error
- Explanation:
- The X server has detected an internal adapter error.
- User Action:
- If you encounter this message, please contact NCD Technical
Support.
CLOSED, adapter closed, interface inactive
- Severity:
- Error
- Explanation:
- The Token-Ring controller on the TRP board has detected a cable
fault and has shut itself down.
- User Action:
- Verify that the cable is intact and securely fastened to the
terminal.
ERROR, internal adapter error
- Severity:
- Error
- Explanation:
- The Token-Ring controller on the TRP board has detected an
internal error.
- User Action:
- If you encounter this message, please contact NCD Technical
Support.
INITFAIL, adapter initialization failed: message
- Severity:
- Fatal
- Explanation:
- The Token-Ring controller on the TRP board has detected an
internal error.
- User Action:
- If you encounter this message, please contact NCD Technical
Support.
OPEN, adapter open, interface active
- Severity:
- Information
- Explanation:
- The Token-Ring controller on the TRP board is working
successfully.
- User Action:
- None
OPENFAIL, adapter open failed: message1 [message2]
- Severity:
- Fatal
- Explanation:
- The Token-Ring controller on the TRP board has encountered an
error while attempting to connect to the Token-Ring network. This error is
described in message1. If the error is irrecoverable, additional information is
provided in message2.
This message may appear if the Token-Ring controller detects a cable fault or
if the terminal is attempting to connect at the wrong ring speed.
- User Action:
- Verify that the terminal is securely attached to the Token-Ring
network and that the terminal is set to the correct speed for communications
across a Token-Ring physical network.
PCMCIAFAIL, PCMCIA initialization failed
- Severity:
- Fatal
- Explanation:
- The PCMCIA card interface failed. The X server has detected an
internal error.
- User Action:
- If you encounter this message, please contact NCD Technical
Support.
STRAYCMD, stray command_type command: command_code
- Severity:
- Warning
- Explanation:
- The Token-Ring controller on the TRP board has detected an
internal error.
- User Action:
- If you encounter this message, please contact NCD Technical
Support.
STRAYINT, stray interrupt_type interrupt
- Severity:
- Warning
- Explanation:
- The Token-Ring controller on the TRP board has detected an
internal error.
- User Action:
- If you encounter this message, please contact NCD Technical
Support.
TXFAIL, transmit failed: message
- Severity:
- Error
- Explanation:
- The Token-Ring controller on the TRP board has detected an
internal error.
- User Action:
- If you encounter this message, please contact NCD Technical
Support.
WAITING, waiting for adapter initialization
- Severity:
- Information
- Explanation:
- The X server is initializing the Token-Ring adapter as requested.
- User Action:
- None
[Top] [Prev] [Next] [Contents] [Index]