[Top] [Prev] [Next] [Contents] [Index]

TOKENRING Messages

TOKENRING messages pertain to Token-Ring communications. If you are looking for a message that refers to the TOKENRING module but does not appear here, refer to "Messages Common to All Modules".


ACCESS, adapter access violation
Severity:
Error
Explanation:
The X server attempted to access Token-Ring reserved, read- only memory.
User Action:
If you encounter this message, please contact NCD Technical Support.

ADAPTERFAIL, PCMCIA adapter initialization failed

Severity:
Fatal
Explanation:
The Token-Ring adapter failed or the X server has detected an internal error.
User Action:
If you encounter this message, please contact NCD Technical Support.

ADDRESS, address for this unit: 00:00:E5:nn:nn:nn

Severity:
Information
Explanation:
The terminal is using the specified Token-Ring address.
User Action:
None

CHECK, adapter CHECK error: hex_values

Severity:
Error
Explanation:
The X server has detected an internal adapter error.
User Action:
If you encounter this message, please contact NCD Technical Support.

CLOSED, adapter closed, interface inactive

Severity:
Error
Explanation:
The Token-Ring controller on the TRP board has detected a cable fault and has shut itself down.
User Action:
Verify that the cable is intact and securely fastened to the terminal.

ERROR, internal adapter error

Severity:
Error
Explanation:
The Token-Ring controller on the TRP board has detected an internal error.
User Action:
If you encounter this message, please contact NCD Technical Support.

INITFAIL, adapter initialization failed: message

Severity:
Fatal
Explanation:
The Token-Ring controller on the TRP board has detected an internal error.
User Action:
If you encounter this message, please contact NCD Technical Support.

OPEN, adapter open, interface active

Severity:
Information
Explanation:
The Token-Ring controller on the TRP board is working successfully.
User Action:
None

OPENFAIL, adapter open failed: message1 [message2]

Severity:
Fatal
Explanation:
The Token-Ring controller on the TRP board has encountered an error while attempting to connect to the Token-Ring network. This error is described in message1. If the error is irrecoverable, additional information is provided in message2.

This message may appear if the Token-Ring controller detects a cable fault or if the terminal is attempting to connect at the wrong ring speed.
User Action:
Verify that the terminal is securely attached to the Token-Ring network and that the terminal is set to the correct speed for communications across a Token-Ring physical network.

PCMCIAFAIL, PCMCIA initialization failed

Severity:
Fatal
Explanation:
The PCMCIA card interface failed. The X server has detected an internal error.
User Action:
If you encounter this message, please contact NCD Technical Support.

STRAYCMD, stray command_type command: command_code

Severity:
Warning
Explanation:
The Token-Ring controller on the TRP board has detected an internal error.
User Action:
If you encounter this message, please contact NCD Technical Support.

STRAYINT, stray interrupt_type interrupt

Severity:
Warning
Explanation:
The Token-Ring controller on the TRP board has detected an internal error.
User Action:
If you encounter this message, please contact NCD Technical Support.

TXFAIL, transmit failed: message

Severity:
Error
Explanation:
The Token-Ring controller on the TRP board has detected an internal error.
User Action:
If you encounter this message, please contact NCD Technical Support.

WAITING, waiting for adapter initialization

Severity:
Information
Explanation:
The X server is initializing the Token-Ring adapter as requested.
User Action:
None


[Top] [Prev] [Next] [Contents] [Index]