There is a problem with the GXT120P and the P202 displays. The screen will come up blank with power managment enabled. In order to have something displayed, the monitor must be powered off and back on.
A workaround for this problem is to disable Power Managment, as detailed in following steps.
Time before display dimmed (in minutes) [0] Time before display power suspended (in minutes) [0] Time before display power turned off (in minutes) [0]
NOTE: The preceding changes will take effect at the next system reboot.
APARS needed to fix this problem are as follows:
[ Doc Ref: 97542155025572 Publish Date: Dec. 13, 2000 4FAX Ref: none ]