TRiP98 FAQ: trouble shooting

<SYS> ...: Not enough space

The meaning of this message is obvious.
Cure

<SYS> ...: No such file or directory

You specified file(s) for input which do not exist or file path(s) for output where the directories do not exist.
Cure
Check existence of input files, in particular the correct expansion of file names which contain environment variables like $TRIP98. For output file paths check that all specified directories exist.

<E> ...: raster position outside scanner limits

Some or a all raster positions would lead to irradiation outside the CT volume.
Cure
One possible reason might be a wrong isocentre specification for example in the field command or a missing z-offset table in a hed-file (old hed-, new vdx-format).