Purpose
Specify analyzer conditions that an event must
satisfy in order to be displayed in live mode
Parameters
number
-
Number of the live display for which conditions are to be defined.
If only one live display is used,
number=1
must be specified.
anlid
-
Name of the analyzer whose condition is to be
used.
cond(c)
-
Condition number of analyzer
'anlid'
which
must be satisfied for display. If omitted, an
event is displayed when the input condition of
analyzer 'anlid'
is satisfied, i.e. when the
latter has been incremented by that event.
list
-
List a table of previously defined live display conditions.
clear
-
Reset previously defined live display conditions.
debug
-
Debug switch. Lots of output !
Function
Remarks
Live display conditions are derived from analyzer
conditions that must be defined and/or
set by a previous command like
DSWI
or
ACDEF
.
DLCND
uses but does not alter analyzer conditions.
A maximum of 10 conditions may be specified for
each live display.
Conditions for live display mode are not
cleared automatically (e.g. after a new
DLIVE
command is given). To start a live display
without conditions, all previously defined live
display conditions must be explicitly reset by
the command
DLCND/CLEAR
.
Examples
DLCND 1 DE / COND(3)
DLCND 1 M
In live display no. 1 events are only displayed
if condition no. 3 of analyzer DE
and the
input condition of analyzer M
are satisfied.
DLCND 3 ENERGY / COND(5)
In live display no. 3 events are only displayed
if condition no. 5 of analyzer ENERGY
is satisfied
DLCND / list
Write a list of previously defined live display
conditions to terminal and protocol.
DLCND 1 /clear
Clear all live display conditions for live display no. 1.