Command DLIVE
| GSI
| Biophysics
| display commands
|
- anlx
- anly
- evtid
- /
- dim()
- window()
- replace()
- points(1000)
- random
- nostop
- debug
Purpose
Display the coincidence of two event parameters in a
two-dimensional scatter plot by marking each event immediately
(live mode)
Parameters
anlx
-
anly
-
Analyzer identifiers for the x- and y-coordinates.
One two-dimensional analyzer may
be displayed in live mode. In this case
'anly'
as well as the keyword dim(d)
must be omitted.
If the analyzer(s) are one-dimensional, or if keyword
dim(d)
is specified, missing analyzers are prompted.
evtid
-
Qualifier for both analyzers.
If omitted, the last specified qualifier is assumed.
dim(d)
-
List of dimension numbers to be displayed in the x- and y-direction in the case of multidimensional analyzers.
If dimension numbers are omitted but required, the user
is prompted. Default in batch mode are the first dimensions.
window(w)
-
List of channel number limits for the x- and y-directions of the segment to be displayed.
w=xmin,xmax,ymin,ymax
.
If a single channel number is omitted, the respective
limit which was effective in the previous DLIVE
command
is taken; startup default and minimum or maximum, respectively, is the corresponding analyzer limit.
An asterisk '*'
stands for the analyzer limit;
w='*'
is equivalent to w='*,*,*,*'
.
Unless in batch mode, limits will be prompted if the
keyword is omitted,
proposing the limits of the previous
DLIVE
command or the analyzer limits, respectively.
replace(n)
-
In a multiple simultaneous live display:
Replace live display number n by the one
currently specified
(see command
DLINIT
).
points(p)
-
Number of live points to be displayed.
random
-
Random numbers between 0 and 1 are added to the x- and
y-coordinates (channel numbers) of a live point.
nostop
-
Option to continue I/O after completion of the live
display. Default: stop I/O (except in on-line mode).
debug
-
Debug switch. Lots of output !
Function
Remarks
The command DLIVE
provides a two-dimensional display
without occupying any computer storage,
i.e. even analyzers without associated spectra (type 0) can be displayed.
A live display will slow down the analysis.
Examples
DL 1 2
Display analyzer no 1 versus analyzer no 2 in live
mode.
DLIVE A
Display the two-dimensional analyzer A
in live
mode.
If analyzer A
is one-dimensional, the second analyzer
is prompted.
| GSI
| Biophysics
| display commands
|
Last updated: M.Kraemer@gsi.de,
4-Aug-1999
Impressum Data privacy protection