Command ALIST
| GSI | Biophysics |

ALIST

anlid evtid
/
window()
zeroes
summed
blockmode
attr
comm()
nobreak
print
outc()
graphic
debug

Purpose

List or print analyzer spectrum and attributes

Parameters

anlid

Analyzer identifier.

evtid

Analyzer qualifier.
Analyzer identifier and qualifier, respectively, may be given by a name or number. A name may contain wild card characters at any position: '%' specifies one character, '*' a (sub)string of any length. If omitted, uniqueness or reference to the last display is assumed.

window(w)

Limits of spectrum output specified by A channel limit omitted in the number list or specified by an asterisk (*) is replaced by the corresponding analyzer limit.

zeroes

Lines containing zeroes are not suppressed.

summed

Output is running sum of spectrum elements.

blockmode

For two-dimensional analyzers only: Subscript of the first (left) dimension varies faster, effecting a layout of the data which is steady in the channel numbers of both dimensions.

attr

Analyzer attributes are included in the output list.

comm(c)

A comment is included in the output. Maximum length: 100 characters.

nobreak

Prompting to break the terminal output is suppressed.

print

The output is sent to a line printer.
Not yet implemented.

outc(p)


Not yet implemented.

graphic

The output is written into the actual picture.
Not yet implemented.
The keywords print and graphic are mutually exclusive. If both are omitted, the output is sent to the terminal.

debug

Debug switch. Lots of output !

Function

The specified spectrum output is created with a line length depending on the analyzer type and the output device. The first element of each output line is preceded by its channel number(s). The maximum integer length is 9 digits; longer numbers are indicated by '***' and appended to the end of the output. Floating point analyzers are listed with format E12.5.
Lines containing only zeroes are suppressed unless zeroes is specified.
The sum of counts of the specified spectrum section is provided after the corresponding list of spectrum elements.

Remarks

Examples

ALIST A1 LIST 
The spectrum contents of analyzer A1.LIST ist listed on the terminal.
ALIST  X%%%88  L*  / PRI ATTR W(101,150)
Attributes and spectrum contents between channel numbers 101 and 150 are immediately printed for all analyzers with names six characters long, beginning with 'X', and ending with '88', and with qualifier names of any length beginning with 'L'.
ALIST  E1 / PRINT  ZEROES  COMM(M 40 Z 18)
The contents of analyzer E1 including zeroes and a comment is immediately printed.
| GSI | Biophysics |
Last updated: M.Kraemer@gsi.de, 3-Aug-1999

Impressum Data privacy protection