Command ALIST
| GSI
| Biophysics
|
- anlid evtid
- /
- window()
- zeroes
- summed
- blockmode
- attr
- comm()
- nobreak
- print
- outc()
- graphic
- debug
Purpose
List or print analyzer spectrum and attributes
Parameters
anlid
-
Analyzer identifier.
evtid
-
Analyzer qualifier.
Analyzer identifier and qualifier, respectively,
may be given by a name or number. A name may contain
wild card characters at any position:
'%'
specifies one
character, '*'
a (sub)string of any length.
If omitted, uniqueness or reference to the last display
is assumed.
window(w)
-
Limits of spectrum output specified by
-
w = *
: analyzer limits (default)
- letter : display window identifier
- one number : analyzer condition number
- number list : lower and upper channel number, given for each dimension
A channel limit omitted in the number list or specified
by an asterisk (*
) is replaced by the corresponding analyzer limit.
zeroes
-
Lines containing zeroes are not suppressed.
summed
-
Output is running sum of spectrum elements.
blockmode
-
For two-dimensional analyzers only: Subscript of the
first (left) dimension varies faster, effecting a layout
of the data which is steady in the channel numbers
of both dimensions.
attr
-
Analyzer attributes are included in the output list.
comm(c)
-
A comment is included in the output. Maximum length:
100 characters.
nobreak
-
Prompting to break the terminal output is suppressed.
print
-
The output is sent to a line printer.
Not yet implemented.
outc(p)
-
Not yet implemented.
graphic
-
The output is written into the actual picture.
Not yet implemented.
The keywords
print
and
graphic
are mutually exclusive.
If both are omitted, the output is sent to the
terminal.
debug
-
Debug switch. Lots of output !
Function
The specified spectrum output is created with a line
length depending on the analyzer type and the output
device. The first element of each output line is preceded
by its channel number(s). The maximum integer
length is 9 digits; longer numbers are indicated by
'***'
and appended to the end of the output. Floating
point analyzers are listed with format E12.5.
Lines containing only zeroes are suppressed unless
zeroes
is specified.
The sum of counts of the specified spectrum section is
provided after the corresponding list of spectrum elements.
Remarks
Examples
ALIST A1 LIST
The spectrum contents of analyzer A1.LIST
ist listed on
the terminal.
ALIST X%%%88 L* / PRI ATTR W(101,150)
Attributes and spectrum contents between channel numbers
101 and 150 are immediately printed for all analyzers
with names six characters long, beginning with
'X'
, and ending with
'88'
, and with qualifier names of
any length beginning with 'L'
.
ALIST E1 / PRINT ZEROES COMM(M 40 Z 18)
The contents of analyzer E1
including zeroes and a comment
is immediately printed.