THERE ARE A NUMBER OF STEPS INVOLVED IN MAKING YOUR OWN MODEM SETUP FILES. THE .MTC FILES ARE STORED IN THE INSTALLDRIVE>:\SYSCTX\TERM SUBDIRECTORY. THEY ARE FLAT ASCII TEXT FILES THAT HAVE THE FOLLOWING FORMAT: /NAME: /CONN: (SEE BELOW) /FLOW: (SEE BELOW) /PAR: /BAUD: /STOP: /DATA: /INITSTR: (SEE BELOW) /HANGUPSTR: /NAME: ENTER A DESCRIPTIVE TITLE FOR THE MODEM THIS WILL APPEAR IN THE SELECTIONS IN CONFIG TERMINALS SCREENS. /CONN: NUMBER THAT IS GENERATED BASED ON THE CONNECT TYPE THAT IS SET UP. THIS NUMBER IS FROM A BIT MAP AS FOLLOWS. CONNECT ON CTS IS 16 CONNECT ON DSR IS 32 CONNECT ON RING INDICATOR IS 64 CONNECT ON DCD IS 128 CONNECT ON FIRST CHARACTER IS 256 DISCONNECT ON BREAK IS 4096 CONNECT ON AUTO BAUD IS 512 YOU ADD UP THE NUMBERS AND PUT THE RESULT IN THIS FIELD. THIS WILL BE AN ITEGER NUMBER THAT WILL CREATE AN EFFECTIVE BIT MAP TO BE USED IN THIS FIELD. /FLOW: NUMBER THAT IS GENERATED BASED ON THE FLOW CONTROL ITEMS THAT ARE SELECTED XON/XOFF TRANSMIT ENABLE IS 256 XON/XOFF FULL DUPLEX IS 8192 RTS/CTS ENABLE IS 16384 RTS INPUT HANDSHAKING IS 32768 DTR/DSR ENABLE IS 1 DTR INPUT HANDSHAKING IS 2 CTS OUTPUT HANDSHAKING IS 8 DSR OUTPUT HANDSHAKING IS 16 DCD OUTPUT HANDSHAKING IS 32 DSR INPUT SENSITIVITY IS 64 THIS IS ANOTHER BIT MAP. JUST ADD UP THE NUMBERS AND PUT THEM IN THIS FIELD. YOU CAN CHECK YOUR WORK ONCE YOU CONFIGURE A TERMINAL BY SEEING IF THE CONTROLS IN CONFIG T MATCH THE BIT MAP YOU HAVE SET UP HERE. /INITSTR: NEEDS TO HAVE YOUR MODEM SPECIFIC COMMANDS IT WILL START WITH "AT" THE ATTENTION COMMAND. YOU WILL HAVE TO CREATE THE REST OF THE STRING USING SOME OR ALL OF THE BELOW LISTED PARAMETERS DECODING THEM TO YOUR SPECIFIC MODEM. ECHO COMMMANDS AUTO ANSWER ON ONE RING SET TO HIGHESTLEVEL OF DATA REL. COMM <%C, OR &K3 OR //N1 ETC> SET TO HIGHEST COMPRESSION RATE SET TO HIGHEST ERROR CORRECTION RATE SET TO DCD CONNECT, OR IF MODEM DOESN'T SUPPORT DCD SET FOR DSR TO TRACK DCD TURN HARDWARE FLOW CONTROL ON TURN SOFTWARE FLOW CONTROL OFF SET MODEM TO THE HIGHEST BAUD RATE SET LINE SPEED TO FLOAT HI SPEED BAUD RATES MIGHT BE <$MB38400 OR $MB ETC> /HANGUPSTR: <~~~+++ATH0^M> THE SIMPLEST WAY TO CREATE THIS FILE IS ACTUALLY TO START WITH AN EXISTING FILE AND MODIFY IT. THE MTC FILES ARE STORED IN THE :\SYSCTX\TERM SUBDIRECTORY. COPY A SIMILAR MODEM TO A NEW FILE WITH A NAME THAT IDENTIFIES YOUR NEW MODEM AND AN EXTENSION OF .MTC. EDIT THIS FILE ONLY ON THE FIRST LINE TO CHANGE THE MODEM NAME TO MATCH YOUR MODEM, THEN SAVE AND EXIT THE FILE. NOW GO INTO CONFIG TERMINALS AND CREATE A NEW TERMINAL PROFILE USING YOUR NEW MODEM MTC FILE. YOU CAN NOW WORK WITH THIS TERMINAL CHANGING ALL OF THE PARAMETERS, SETUP STRINGS AND HANG UP STRINGS AND FLOW AND CONNECT INFROMATION UNTIL THE MODEM IS RESPONDING CORERECTLY AND RELIABLY. YOU WILL BE SAVING THIS TERMINAL CONFIGURATION EVERY TIME YOU PRESS F2 WHILE YOU ARE DOING YOUR DEVELOPMENT WORK. IT IS SAVED IN THE :SYSCTX\TERM SUBDIRECTORY UNDER THE NAME OF THE TERMINAL PROFILE. (UNDER HPFS IT WILL HAVE A LONG NAME PREFACED BY TC.) YOU CAN PRINT OUT THE TERMINAL PROFILE AND MANUALLY ENTER THE APPROPRIATE VALUES INTO THE MASTER NEW MTC FILE FOR THIS MODEM THAT YOU PREVIOUSLY CREATED. ( COPY THE FLOW VALUE, CONNECT VALUE, INIT STRING, HANGUP STRING) YOU CAN THEN CREATE ANOTHER TERMINAL( NEW NAME SO YOU DON'T DESTROY YOUR WORKING TERMINAL) AND TEST IT FOR OPERATION. IF IT WORKS CORRECTLY YOU ARE DONE, IF NOT YOU SHOULD COMPARE THIS TERMINAL TO THE WORKING TERMINAL FILE AND NOTE AND CORRECT THE DISCREPANCIES. THIS IS NOT AN EASY PROCEDURE BUT IT IS POSSIBLE FOR YOU TO CREATE YOUR OWN. WE WILL WORK TO HELP YOU IF YOU HAVE PROBLEMS. WE CONSTANLY UPDATE OUR LIST OF SUPPORTED MODEMS IN A FILE ON THE CITRIX BBS CALLED MODEMS.ZIP THE BBS NUMBER IS 305-346-9004. USE PROCOMM PLUS OR SIMILAR PROGRAM SET TO N81 AND GET THE LATEST FILE. NOTE: IF A COMMAND IN THE HOST INIT STRING REQUIRES A "\" CHARACTER YOU NEED TO HAVE TWO IN A ROW. THIS WILL BE FIXED TO ONE IN A FUTURE RELEASE.